Click Here to Contact Us
x

Contact Form

 

Products & Services

In Use Testing

Callington Haven can provide testing services for all NDT products, see below.

Schedule of In-Use Penetrant Materials Testing

  MIL-STD-6866 ASTM-E-1417
  Paragraph Frequency Paragraph Frequency
Penetrants        
Fluorescent Brightness 5.8.4.1.1 quarterly 7.8.4.1 quarterly
Water Content (Method A only) 5.8.4.1.2 monthly 7.8.2.2 monthly
Removability (Method A only)* 5.8.4.1.3 monthly 7.8.4.2 monthly
Sensitivity* 5.8.4.1.4 monthly 7.8.4.3 weekly
Viscosity   optional   optional
Water Tolerance   optional   optional
Contamination/Separation*   optional 7.8.2.1 optional
Emulsifiers        
Removability (Method B&D)* 5.8.4.2.1 weekly 7.4.4.4 monthly
Water Content (Method B) 5.8.4.2.2 monthly 7.8.2.3 monthly
Magnetic Particle Bath - ASTM E-1444        
Viscosity     5.8.3 monthly
Background Fluorescence     7.1.4.1(2) monthly

* Removability, Sensitivity, and Separation are often tested locally by the user.